X-Ray Tube to test tyre

Tyre Inspection X-Ray Tube could be either fixed in directional or panoramic radiation machine. The x-ray tube is designed for tyre inspection applications.

The highlights of these tubes are small focal spots, clear image quality, high reliability.

Specification

Target materialW
Nominal focal spot ( EN12543-2 )0.4×4.5mm
Anode angle21° conical
Emission angle33°×280°
Inherent filtration2mm Be
Absolute maximum ratings
Constant DC voltage120kV
Anode load for tungsten target480W
Filament data4.3A (4.3V)
Anode current8mA
High tension socketR24 rtw type
ContactingLarge focal spot
Cooling medium
Water flow rate min.4 L/min@3 bar
Water pressure max.6 bar
Water temperature at inlet max.35℃
Environmental conditions
Environmental temperature when use-10℃ - +70℃
Relative humidity when usemax 95%
Store temperaturewater entirely removed
Weight1.7kg
ApplicationTire NDT Application