380kv Portable X-Ray Machine

380kv Portable X-Ray machine is a hot seller in markets, it has a high penetration power of more than 60mm stainless steel.

General Introduction of 380kv Portable X-Ray Machine

The 3805 series machines have the most penetrating ability among all portable X-ray flaw detectors. In 2006, our company took the lead successfully developing 3805 flaw detector in China.

Chinese first x-ray tube was produced in 1965 by Ronghua company. After that, in 1976, we produced industrial portable x-ray machine. Till now, we have tens of  years  of experience in manufacturing this machine, and the technical requirements of this product exceeds that of Japanese.

This 380kv series machines have been well popular and the first choice to replace the mainframe.

Features of 380kv portable x-ray machine

1  First, the main components of its controller: the device parameters remain unchanged under the fluctuation of ambient temperature, ensuring the controller stable and reliable under its high power operation;

2  Second, the transformer core: can reduced the eddy current and     hysteresis loss to the most, which consequently minimize the heat radiation generated by the transformer;

3  Third, the high-voltage coil: special material and design ensures it working stably for a long time in a reasonable temperature range;

4  Specially made x ray tube ensures high emission efficiency;

5  Due to two heating radiation system inside and outside of the generator, the heating radiation efficiency makes the temperature outside the generator remains still.

Specifications of 380kv Portable X-Ray Machine

General DescriptionDetailed ItemXXG-3805XXGHZ-3805
InputPower SupplySingle phrase  50Hz,
AC 220 ± 10% V
Power capacity4kv
Fluctuation of input voltage±1%
OutputX ray tube peak voltage 210-380kv
X ray tube current (average value)5mA
ControllerDimension (length×width×height)350×290×155mm
Weight10kg
X ray tubeFocus size 3.0×3.0(mm×mm)1.5×2.5(mm×mm)
X ray radiation angle40°+5°
X Ray GeneratorCoolingby forced air
InsulationSF6 gas
Safety working voltage0.36Mpa ~ 0.45 Mpa
Dimension (length×width×height)Φ340×750 mmΦ340×770 mm
Weight 35kg38kg
Max. Penetration thicknessSteel board  A3 69mm59mm
Exposure Standard Condition1. Focus distance: 600mm, exposure time: 5 minutes;
2. Tianjin Ⅲ film, double lead foil intensifier screen; sensibility ≤1.5%;
3. Processing in dark room: temperature: 20 ± 2℃;
4. development time: 5 minutes, darkness ≥1.5.
Working ConditionTemperature– 30 ~ + 40℃
Relative humidity≤85%
Height above sea level≤1000 meters
Working Cycle1:1

Get a quote for this now: